ITAS - Ekspert på målesystemer

Produkter fra alle leverandører: Sensorer Meteorologi   Luftfukt   Produkter fra denne leverandøren: Campbell Scientific   Sensorer Meteorologi   

WXT520

  • Measures 6 most essential weather parameters as WXT510
  • Accurate and stable
  • Low power consumption - works also with solar panels
  • Compact, light-weight
  • Easy to install
  • No moving parts
  • Vaisala Configuration Tool for PC
  • USB connection
  • Housing with mounting kit IP66
  • Applications: weather stations, dense networks, harbors, marinas
  • All WXT510's sent to Vaisala for service will be upgraded to WXT520

Produsent/Leverandør: Vaisala

Spesifikasjoner

Wind speed

 

Speed
Measurement range
Accuracy
0 ... 35 m/s
36 ... 60 m/s

Direction
Measurement range
Accuracy
Response time


0 ... 60 m/s

±0.3 m/s or ±3%, whichever is greater
±5%


0 ... 360°
±3°
250 ms

Liquid precipitation

 

Rainfall

output resolution
accuracy

Rainfall duration

output resolution

Rain intensity
range
output resolution

cumulative accumulation after latest automatic or manual reset
0.01 mm, 0.001 inches
5%*

counting each ten-second increment when droplet detected
10 s

one-minute running average in ten-second steps
0 ... 200 mm/h (broader range with reduced accuracy)
0.1 mm/h, 0.01 inches/h

Barometric pressure

 

Measurement range
Accuracy

600 ... 1100 hPa
±0.5 hPa at 0 ... 30 °C (+32 ... +86 °F)
±1 hPa at -52 ... +60 °C (-60 ... +140 °F)

Air temperature

 

Measurement range
Accuracy at +20 °C (+68 °F)

-52 ... +60 °C (-60 ... +140 °F)
±0.3 °C (±0.5 °F)

Relative humidity

 

Measurement range
Accuracy

0 ... 100 %RH
±3 %RH within 0 ... 90 %RH
±5 %RH within 90 ... 100 %RH

General

 

Operating temperature
Storage temperature
Input voltage
Typical power consumption
Heating voltage
Serial data interface
Housing
Housing with mounting kit
Electromagnetic compatibility
IEC standards

-52 ... +60 °C (-60 ... +140 °F)
-60 ... +70 °C (-76 ... +158 °F)
5 ... 32 VDC
3 mA at 12 VDC (with defaults)
5 ... 32 VDC (or AC, max. 30 VRMS)
SDI-12, RS232, RS485, RS422, USB adapterr
IP65
IP66
complies with EMC standard EN61326-1; Industrial Environment
IEC 60945/61000-4-2 ... 61000-4-6